Buehlmann


Angiotensin II

Angiotensin II has a key position in the Renin-Angiotensin-Aldosterone-System (RAAS), which maintains blood pressure and regulates the bodies water balance. The BÜHLMANN Angiotensin II RIA was one of the first commercially available Angiotensin II RIA Kits available on the market. It is currently used in both clinical routine labs in addition to a number of research projects investigating hyper- and normo-tensive animal models inrat and mouse.

The clinical use in routine labs is dedicated to:

test

• Diagnosis of hypertension: Angiotensin II is a pivotal molecule in the blood pressure regulatory loop controlled by the RAAS. Increased interest has developed in measuring Angiotensin II during either diagnosis of hypertension or the maintenance phase of therapy.

• Treatment with Angiotensin Converting Enzyme-Inhibitors (ACE-I): the short-term plasma Angiotensin II level reflects a re-setting of the RAAS at a given level of ACE-inhibition. Long-term therapy with ACE-I is frequently accompanied by a re-bound of Angiotensin II, with a return towards pre-therapy levels. The implications of this re-bound of Angiotensin II may justify careful monitoring of Angiotensin II during long term therapy.

• Treatment with Angiotensin II Receptor antagonists: a new generation of anti-hypertensive drugs has recently been introduced. Similar to ACE-I, these drugs induce a reactive rise in plasma renin activity, Angiotensin I and, unlike ACE-I, an immediate rise in Angiotensin II.

• Angiotensin II as enhancer of lipid peroxidation: patients with essential hypertension show an increased risk for arteriosclerosis that may be related to factors in addition to the level of blood pressure. Although the involvement of circulating Angiotensin II in arteriosclerosis has not been proven, the underlying possibility that Angiotensin II may be involved has raised interest in measuring this parameter. 

Advantages of the BUHLMANN Angiotensin II RIA:

Sampling ease:

EDTA-plasma is stabilized with ready-to-use Bestatin

Sensitivity:

0.68 pg/ml

Specificity:

<0.14% crossreactivity with Angiotensin I

Reproducibility:

Pre-measured standards and two controls ensure low inter-assay variation.

Accuracy:

Expected value range is similar to HPLC:0.9 - 13.8 pg/ml, mean = 5.9 pg/ml

Downloads

Instruction for use*

Technical information

Labelling schedule

Englisch

[PDF 350 KB] [PDF 620 KB] 2013 [PDF 150 KB]

 * Multilingual [EN, DE, FR, IT, ES]


Contact

BÜHLMANN Laboratories AG
Baselstr. 55
CH-4124 Schönenbuch
Switzerland
Fon: +41 61 487 12 12
Fax: +41 61 487 12 34
info@buhlmannlabs.ch

Distributors
Order
About us
Job opportunities

News

Calprotectin ELISA Automation

BÜHLMANN has set a focus on automation of its ELISA tests, starting with Calprotectin. A number of validated protocols are available on the commonly use  more

Interviews from Dr. Christoph Noppen (Viollier, Allschwil) about the EGFR test from EntroGen and from Dr. Günter Dollenmaier (ZLMSG) about the Anyplex II RV16 test from Seegene

Please read the two new success stories with our new products. You will find the interview with Dr. Christoph Noppen about the evaluation of the EGFR Rea  more

Interviews on calprotectin by BÜHLMANN on the National Health channel UK

TV programme on calprotectin diagnosis for IBD and BÜHLMANN Laboratories on the NHS National Health Channel in the UK. The interviews are scheduled to be  more

BÜHLMANN releases a new calprotectin test

CALcheck Blue™ is a rapid qualitative screening test. Easy to use, with Quick Prep extraction, no pipetting, no vortexing , reaction time of 10 minutes to  more

Get our RSS - Feed