Buehlmann


Quantification of ACE activity in CSF


ACE high sensitive

Reliable and sensitive quantification of Angiotensin Converting Enzyme (ACE) activity in
Cerebrospinal fluid (CSF) is still a challenge.  BÜHLMANN provides the first commercial CE marked and non-radioactive tool, allowing reliable ACE determination in CSF.


 High sensitive Assay

The BÜHLMANN ACE high sensitive assay is designed to quantify reproducibly increased ACE activity in CSF samples from suspected and confirmed  neurosarcoidotic patients. ACE activity measurement in diluted serum samples is possible as well.

The assay shows a detection limit of 1 U/L and can be applied either on microtiter plates with a kinetic reader or on some clinical chemistry analyzers. The determined dynamic range goes up to 24 U/L. Results can be retrieved within about half an hour.

The standardization of the assay is based on the well established  BÜHLMANN ACE kinetic assay for serum testing (order code: KK-ACK).

The prinicple of the assay is based, as in the ACE kinetic assay, on the cleavage of the synthetic substrate FAPGG into an amino acid derivate and a dipeptide. The kinetic of this cleavage reaction is measured by recording the decreasing absorbance at 340 nm.

ACE high sensitive
Method

Enzymatic Assay (kinetic)
- on microtiter plates with kinetic reader
- Analyzers (Pentra, KoneLab, Cobas Mira)

Time to Result ~30 min
Sample Type CSF / Serum (1:5)
Sensitivity 1 U/L
Dynamic Range 1.5 - 24 U/L
Order Code KK-ACF   130 tests

CE
Downloads


Instruction for use* Technical product information
english             
PDF [200 KB] PDF [200 KB]

* Multilingual document [EN, DE, FR, IT, ES]

ACE – Angiotensin Converting Enzyme

ACE is a membrane-bound glycoprotein produced by epithelioid cells of granulomatous tissue and was first reported to be increased in CSF in patients with neurosarcoidosis in the mid-1980s by Schweisfurth et al. Elevated levels understandably occur with other granulomatous diseases (typically rare in neurologic practice) but reports also suggest increased levels in association with CNS tumors and infections such as meningitis.

Neurosarcoidosis

Sarcoidosis is a multisystem granulomatous disorder of unknown etiology and can be present in any organ system. Most commonly it occurs in lungs, followed by the eyes and integument. Nervous system involvement is present in approximately 5% of cases. Multiorgan involvement is a strong clue pointing to sarcoidosis, but the disease may be restricted to the nervous system. Diagnosis may be difficult, or at least delayed, because the clinical presentation and course of the disease is heterogeneous.
A valid, reproducible marker with reasonable sensitivity and specificity for sarcoidosis could influence the degree of pursuit of the diagnosis and likelihood of finding an appropriate biopsy target. A confident diagnosis of neurosarcoidosis requires histologie confirmation of involved nervous system tissue.

Contact

BÜHLMANN Laboratories AG
Baselstr. 55
CH-4124 Schönenbuch
Switzerland
Fon: +41 61 487 12 12
Fax: +41 61 487 12 34
info@buhlmannlabs.ch

Distributors
Order
About us
Job opportunities

News

Calprotectin ELISA Automation

BÜHLMANN has set a focus on automation of its ELISA tests, starting with Calprotectin. A number of validated protocols are available on the commonly use  more

Interviews from Dr. Christoph Noppen (Viollier, Allschwil) about the EGFR test from EntroGen and from Dr. Günter Dollenmaier (ZLMSG) about the Anyplex II RV16 test from Seegene

Please read the two new success stories with our new products. You will find the interview with Dr. Christoph Noppen about the evaluation of the EGFR Rea  more

Interviews on calprotectin by BÜHLMANN on the National Health channel UK

TV programme on calprotectin diagnosis for IBD and BÜHLMANN Laboratories on the NHS National Health Channel in the UK. The interviews are scheduled to be  more

BÜHLMANN releases a new calprotectin test

CALcheck Blue™ is a rapid qualitative screening test. Easy to use, with Quick Prep extraction, no pipetting, no vortexing , reaction time of 10 minutes to  more

Get our RSS - Feed